Fluke 902 Review: Great Choice to Measure Current and Voltage Safely
Fluke 902 Clamp meter is one of the best clamp meter than other brands here we going to more discuss about Fluke 902 Clamp meter.
The 902 FC is a true RMS clamp meter that can measure voltage and current. Unlike the Fluke 325, the Fluke 902 FC has more special features. One of its features is the compatibility of wireless devices with the Fluke Connect system. The Fluke 902 FC is an exceptional system that gives you unparalleled flexibility at work and makes damage and measurement easier and faster. It is a no-mess clamp meter-cum-multimeter that provides you the service of both applications.
It performs well in tough places and can easily measure voltages and currents. To learn more about the device, you can read it in the Fluke 902 review below.
Fluke 902 FC HVAC True-RMS Clamp Meter
Features of Fluke 902 FC
Fluke 902 FC can be used alongside company lines of wirelessly connected equipment. You can also measure logs and trends to find intermittent errors, and then send the results to the official mobile app. This allows you to send reports while on the field and measure efficiently without leaving the surrounding area. The Fluke 902 FC was originally designed for HVAC technologists and is featured for these applications. Some include:
- Increased resistance range to measure DC range and wide set of thermistors.
- Bright backlight display
- Ability to measure capacitance and contact temperature
- Minimum / maximum functions
Specifications: Fluke 902 FC True-RMS HVAC Clamp Meter
Function | ||
A ac (via Jaw) | ||
Resolution | 0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 [email protected] A > 1.4 [email protected] A Add 2% for CF>400 A | |
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -40 to 400 °C (-40 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) | |
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) | |
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | Pollution Degree 2, IEC 61010-1 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V | |
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
Performance
Fluke 902 FC is capable of measuring current up to 600 AC and voltage up to 600 V AC / DC. You can measure capacitance (up to 1000 μF) and resistance (up to 60 kg). The Fluke 902 FC DC micrometer can measure up to 200 μF. As for temperature, 902 FC can measure between -10-degrees to 400-degrees. The device is equipped with minimum / maximum recording.
Design
The Fluke 902 FC is built with a stiff case and a raw jaw mechanism that is strong and durable. Thanks to its narrow body, you can easily use the device only in hard angles like tube and trucking. Additionally, changing the battery is a breeze. However, compared to other clamp meters, it is not as durable as it seems.
Safety and warranty
The Fluke 902 FC features an IP30 rating in contrast to dust and water. It also has a 3 year warranty period. The device is also protected by CAT IV 600 V and CAT III 1000 V.
Buying guide
Here are some things to keep in mind when looking for the best clamp meter:
Safety
The most important aspect you should consider when looking for the best clamp meter is the amount of protection it can provide. This can be easily determined by the build quality and material of the device. A secure clamp meter needs to have higher resistance and current rating and overall voltage. Additionally, devices must have all regulatory certificates.
Maximum resistance limit
The resistance of a clamp meter is measured in ohms and will give you how much flow the device can stop. You will get a rough idea of how hard it is for the current to flow through the conductor. In most cases, the clamp meter has a resistance limit of at least 4 KΩ. However, there are some models that can have a resistance limit of 10 KΩ. If you regularly deal with heavy transport equipment and tools, it is advisable to choose a clamp meter with a resistance limit of 20 KΩ.
Clamp size
Clamp size refers to the starting edge of a machine. These startups are the holders that are used to hold the conductor. The size of the opening ranges from 18 mm to 45 mm. Clamps are available in different sizes. The clamp meter clamp size should be able to contract or extend so that the conductor can fit easily. Besides, they need to be done without hands so that you do not have to physically touch the conductor.
Crest factor
A clamp meter crest factor means measuring current in the waveform. To find this value, you need to measure the current top value as opposed to the RMS value (root mean square), this will be important to you as it will help you understand the overloads of the circuit.
Backlit screen
Most electrical jobs are in poorly lit and dark areas so, reading screens can become difficult. The clamp meter you choose needs to have a screen with a backlight that allows you to read the measurements more easily.
Warranty
Clamp meter expensive equipment; Therefore you must choose what comes with a warranty period. You can get cheaper devices on the market, but they have no warranty and have the highest chance of breaking. Opt for a clamp meter that offers a warranty period of at least 1 year. Some brands even offer a warranty period of up to 3 years.
Compatibility to smartphone
Nowadays, clamp meters are compatible with your smartphone device via IR communication or Bluetooth. This will allow you to work without having to physically approach the meter to check the measurements. In addition to being highly secure, you can toggle and tune the meter from your smartphone, which also includes email correspondence, real-time report sharing, and cloud storage on quite efficient devices.